5-28 Motion Mate™ DSM314 for Series 90™-30 PLCs User's Manual
–
January 2001 GFK-1742A
5
Example 1:
In this example, the
Servo Axis 1 Actual Velocity
signal (Signal Code=15) is re-routed from its
default output on Connector A to Connector B (Connector Code=02h), replacing any previous
signal on Connector B. This is accomplished by placing the following data in the %AQ
immediate command words:
Word 2
(Byte 5 and Byte 4)
Word 1
(Byte 3 and Byte 2)
Word 0
(Byte 1 and Byte 0)
+00000 +00015 0247h
Example 2:
In this example, the
Servo Axis 1 Torque Command
signal (Signal Code=10) is selected as the
Analog Output on Connector D (Connector Code=04h), replacing any previous signal on
Connector D. To accomplish this, place the following data in the %AQ immediate command
words:
Word 2
(Byte 5 and Byte 4)
Word 1
(Byte 3 and Byte 2)
Word 0
(Byte 1 and Byte 0)
+00000 +00010 0447h
Example 3:
In Example 2, the %AQ
Force Analog Output
default signal was replaced as the Analog Output
on Connector D by the
Servo Axis 1 Torque Command
signal
.
To restore the %AQ
Force Analog
Output
signal (Signal Code=00) to Connector D (Connector Code=04h), place the following data
in the %AQ immediate command words:
Word 2
(Byte 5 and Byte 4)
Word 1
(Byte 3 and Byte 2)
Word 0
(Byte 1 and Byte 0)
+00000 +00000 0447h
elect Analog Output Mode
ommand Code (47h)
arget Connector
ode (04h)
Signal Code (10)
elect Analog Output Mode
ommand Code (47h)
arget Connector
ode (04h)
Signal Code (00)
elect Analog Output Mode
ommand Code (47h)
arget Connector
ode (02h)
Signal Code (15)